Eurotherm Epack 3PH

From £1,137.00 (+ VAT)

EPack-3PH Compact SCR Power Controllers

OEMs and system integrators need to be able to react quickly to customer needs while maximizing resources. End users continually need to improve operational efficiency and productivity. Eurotherm EPackTM- 3PH Compact SCR Power Controllers have been designed to deliver real savings, helping to reduce energy costs. Quick and easy to install, integrate and commission. Compact, with powerful and versatile features that help minimize costs whilst improving productivity and quality.

  • Improved energy consumption to help reduce energy bills
  • Help maximize yield with accurate and repeatable control
  • Customizable options provide better value for money
  • Easy to specify with reduced number of hardware variants
  • Fast integration and commissioning
  • Monitor efficiently with integrated measurements
  • Simplified design reduces stock and spares holding

Key Features

  • Native communication: Modbus® TCP and EtherNet/IP or PROFINET comms for easy connection to PLC
  • True power control with current limitation
  • Large voltage capability from 100V to 500V adjustable in the same variant
  • Measurements: current, voltage, power, impedance, energy usage and more
  • SCCR 100kA with fuse

Product download

Spec sheet

Maximum Current

Warning 1) If control type does not include current limit function by phase angle reduction (V2CL or PWRCL control mode): calculate the maximum current of the load by taking into account of load resistive tolerance (tolerance and variation due to temperature) and voltage tolerance. --> With voltage tolerance of +10% and load resistance manufacture tolerance of +/- 5% and load resistance variation in temperature of +/- 7% the product rating have to be equal or greater than 1.25 x I load nominal (where 1.25 = 1.1/(0.93x0.95)). 2) If control type does include current limit function by phase angle reduction (V2CL, PWRCL): the current limit function by phase angle reduction may be selected to limit the inrush current of the load and reduce the current rating of the product (select "Enable" for "I Limit" In quick code with V2CL or PWRCL control types.) --> With current limit function by phase angle reduction, select the product current rating greater than or equal to the nominal current of the load. Setting of current limit function by phase angle reduction must be lower or equal to product current rating. Warning: Due to load and mains voltage fluctuation and tolerance, it is advised to keep a margin factor of 1.2 when calculate the max current rating of the product. It will prevent to keep the current limitation by phase angle reduction always active. The product installation has to follow the product specifications and environmental constraints in temperature and altitude. Note that duty cycle current limiting feature in burst mode (when IHC, BF or FX + TFR option); does not limit the peak current value. Select the product current rating greater than or equal to the MAXIMUM current of the load. Failure to follow these instructions will result in death or serious injury. If SWIR (Short Wave Infrared) load type is used: 3) --> With SWIR Load, if a fast response time is required (firing mode IHC, PA or BF), select SWIR (Infrared) as Heater type. If SWIR is selected as Heater type, select the product current rating greater than or equal to 125% of MAXIMUM current of the SWIR load WITHOUT taking in account the inrush current due to load variation in temperature. Adjust the duration of the safety ramp (SafetyRamp) and the cooling time of the load (SWIRLoadCoolingTime), to limit the RMS load inrush current SWIR to less than 2.5 times the product current rating. With voltage tolerance of +10% and load resistance manufacture tolerance of +/- 10% the product rating have to be equal or greater than 1.53 x I load nominal (where 1.53 = 1.25 x 1.1/0.90). 4) --> With current limit function by phase angle reduction, select the product current rating greater than or equal to the nominal current of the load. Setting of current limit function by phase angle reduction must be lower or equal to product current rating. Warning: Due to load and mains voltage fluctuation and tolerance, it is advised to keep a margin factor of 1.2 when calculate the max current rating of the product. It will prevent to keep the current limitation by phase angle reduction always active. The product installation has to follow the product specifications and environmental constraints in temperature and altitude. Note that duty cycle current limiting feature (Transfer option in burst mode); does not limit the peak current value. Select the product current rating greater than or equal to the MAXIMUM current of the load. Failure to follow these instructions will result in death, serious injury or equipment damage.

Auxiliary Power Supply

Control Option

Transfer Option

Energy Option

Comms Option

OEM Security

Warranty

Graphical Edition

Fuse

Configuration

Product price: £1,137.00
Total options:
Order total:

Quantity

Delivery times vary, please speak to a member of our team for confirmation.