tel: (+44) 1625 618526 | email: dh@electroserv.co.uk

Thermocouple Application Specific Types

ETC PI MP  
The ETC PI MP is a thermocouple manufactured to monitor the temperature of the melt plastic in plastic moulding machines. The assembly is manufactured in stainless steel and has a long mounting thread enabling the probe to be inserted into the plastic melt. The element is isolated from the sheath. Operating temperature range is 0-500°C and termination is via a standard thermocouple plug. electroserv ltd - thermocouples - pimp
ETC PI LT  
24mm x 13mm x 0.5mm.Leaf Type Thermocouple, often used to measure temperatures under heater bands. This fast response probe can be supplied with any length of metal braided glass fibre insulated cable. Please specify thermocouple calibration and lead length. electroserv ltd - thermocouples - pilt
ETC PI WT  
The Washer Thermocouple is a convenient configuration which allows temperature to be monitored in a variety of applications. The standard washer dimensions are as shown in the drawing but many variations are available. Please specify washer dimensions required, calibration type and lead length. electroserv ltd - thermocouples - piwt
ETC GP RT  
The Ring Type Thermocouple has been designed to allow the temperature of pipes to be monitored using a jubilee type clamp. The thermocouple junction is housed in a small protection sheath attached to the clamp. Please specify clip diameter, calibration and lead lengths. electroserv ltd - thermocouples - gprt
ETC PI NZ  
Nozzle Bolt Type thermocouples are available in calibration types K, J and T. Normally constructed as per drawing below they can be supplied in a variety of configurations. Please specify bolt thread, calibration types and lead lengths. electroserv ltd - thermocouples - pinz
ETC TS WJ  
Thermocouples with Teflon covered Leads 1/0.5mm dia. Welded junction, max insulation temperature 260°C.
OREDR CODE
ETC TS WJ LL  
Calibration Lead Length Code
K (Max junction temperature 1000°C) 250mm 0250
J (Max junction temperature 750°C) 500mm 0500
T (Max junction temperature 450°C) 1mtr 1000
  2mtrs 2000
  5mtrs 5000

ORDER EXAMPLE: ETC TS WJ K LL 1000 -
Thermocouple Series ETC TS WJ with Type K calibration & 1 metre lead.
electroserv ltd - thermocouples - tswj
ETC TM WJ  
Thermocouples with Teflon covered Multi Stranded Leads 7/0.2mm Welded junction, max insulation temperature 260°C.
OREDR CODE
ETC TM WJ LL  
Calibration Lead Length Code
K (Max junction temperature 1000°C) 250mm 0250
J (Max junction temperature 750°C) 500mm 0500
T (Max junction temperature 450°C) 1mtr 1000
  2mtrs 2000
  5mtrs 5000

ORDER EXAMPLE: ETC TM WJ J LL 0500 -
Thermocouple Series ETC TM WJ with Type J calibration & 500mm lead.
electroserv ltd - thermocouples - tmwj
ETC GS WJ  
Thermocouples with Glass Fibre Covered Leads 1/0.5mm dia. Welded junction, max insulation temperature 400°C.
OREDR CODE
ETC GS WJ LL  
Calibration Lead Length Code
K (Max junction temperature 1000°C) 250mm 0250
J (Max junction temperature 750°C) 500mm 0500
T (Max junction temperature 450°C) 1mtr 1000
  2mtrs 2000
  5mtrs 5000

ORDER EXAMPLE: ETC GS WJ K LL 1000 -
Thermocouple Series ETC GS WJ with Type K calibration & 1 metre lead
electroserv ltd - thermocouples - gswj
ETC GM WJ  
Thermocouples with Glass Fibre covered multi stranded leads 7/0.2mm Welded junction, max insulation temperature 400°C.
OREDR CODE
ETC GM WJ LL  
Calibration Lead Length Code
K (Max junction temperature 1000°C) 250mm 0250
J (Max junction temperature 750°C) 500mm 0500
T (Max junction temperature 450°C) 1mtr 1000
  2mtrs 2000
  5mtrs 5000

ORDER EXAMPLE: ETC GM WJ T LL 0500 -
Thermocouple Series ETC GM WJ with Type T calibration & 500mm lead.
electroserv ltd - thermocouples - gmwj
ETC MP SP  
Thermocouples are attached to an adhesive patch which allows easy application. The max operating temperature is 200°C. Supplied with 1/0.5mm Teflon insulated lead wire they provide a convenient method of surface temperature measurement.
OREDR CODE
ETC MP SP LL  
Calibration Lead Length Code
K (Max junction temperature 1000°C) 250mm 0250
J (Max junction temperature 750°C) 500mm 0500
T (Max junction temperature 450°C) 1mtr 1000
  2mtrs 2000
  5mtrs 5000

ORDER EXAMPLE: ETC MP SP T LL 2000 -
Thermocouple Series ETC MP SP with Type T calibration & 2 metre lead.
electroserv ltd - thermocouples - mpsp
ETC MP MB  
Thermocouples spring loaded into a button magnet for application where temperature measurement of Ferrous material is required. Having PTFE insulated leads this can be a convenient method of measuring surface temperatures. Max operating temp 250°C.
OREDR CODE
ETC MP MB LL  
Calibration Lead Length Code
K (Max junction temperature 1000°C) 250mm 0250
J (Max junction temperature 750°C) 500mm 0500
T (Max junction temperature 450°C) 1mtr 1000
  2mtrs 2000
  5mtrs 5000

ORDER EXAMPLE: TC MP MB T LL 2000 -
Thermocouple Series TC MP MBJ with Type T calibration & 2 metre lead.
electroserv ltd - thermocouples - mpmb
electroserv ltd - thermocouples - mich

specification sheet

To view and download a specification sheet for ETC PI MP, PI LT, PI WT, GP RT, PI NZ click here.

electroserv ltd - thermocouples - tswj

specification sheet

To view and download a specification sheet for ETC TS WJ, TM WJ, GS WJ, GM WJ, MP SP, MP MB click here.

Adobe Acrobat reader is required, use the link below to download it.

electroserv ltd - adobe reader logo
Electroserv (TC & S) Ltd, PO BOX 163, 6 Short Street, Macclesfield, Cheshire, England UK, SK11 8GA
designed by focus systems ltd © 2007