West 8600 1/8 DIN Plastics Controller
TECHNICAL DATA
| Features | |
| Control Types | Full PID with Pre-tune, Self-tune, Manual Tuning, or On-Off control. Heat only or heat & cool |
| Soft Start | Allows lower SP value and cycle time during the process start-up phase |
| Auto/Manual | Selectable from front panel, with bumpless transfer. Instant power-off feature also available as standard |
| Output Configuration | Up to 4 total. Max 2 for control (Heat & Cool), max 3 for Alarms, max 1 for retransmit Process value or Setpoint |
| Process Alarm Types | Process high, process low, SP deviation, band, logical OR |
| Heater Break Alarm Types | Current low or high, (in absolute amps or % of nominal current) plus contactor/thyristor short circuit |
| Human Interface | Human Interface 4 button operation, dual 4 digit 10mm & 8mm high LED displays, plus 3 LED indicators |
| PC Configuration | Off-line configuration from serial port to dedicated config socket (comms option not required) |
| Input | |
| Thermocouple | J, K, R, S, T, B, L, & N. |
| RTD | 3 Wire PT100, 50 Ohm per lead maximum (balanced) |
| Impedance | >100M Ohm |
| Accuracy | +/- 0.25% of input span +/- 1 LSD (T/C CJC better than 0.7°C) |
| Sampling | 4 per second, 14 bit resolution approximately |
| Sensor Break Detection | < 2 secs, control O/P's turn off, high alarms activate for thermocouple ranges, low alarms activate for RTD |
| Heater Current | 0-50mA secondary from external current transformer. Display is scaleable up to 100 amps |
| Output and Options | |
| Control & Alarm Relays | Contacts *SPDT 2Amp resistive at 240V AC,>500,000 operations.*Dual relay=SPST for O/P's 2 & 4 |
| Control SSR Driver Outputs | Drive capability, output 1= >10V DC into 500 Ohm min, output 2= >4.3V DC into 250 Ohm min |
| Solid State (Triac) Outputs | 0.01 to 1 Amp AC 20 to 280V, 47 to 63Hz |
| Retransmit Outputs | 0-20/4-20mA into 500 Ohm max, 0-10/0-5V into 500 Ohm min. Accuracy typically +/- 0.25% |
| Communications | 2 Wire RS485, 1200 to 9600 Baud, Modbus or West ASCII (Selectable) |
| Dual SP/Current Transfer | Volt free or TTL input. Selects between 2 setpoints or quick transfer of heater current as nominal value |
| Operating and Environmental | |
| Temperature & RH | 0 to 55°C (-20 to 80°C storage), 20% to 95%RH non-condensing |
| Power Supply | 100 to 240V 50/60Hz 7.5VA (optional 20 to 50V AC 7.5VA/22 to 65V DC 4W) |
| Front Panel Protection | IEC IP66 (Behind panel protection is IP20) |
| Approvals and Certification | CE, UL & ULc |
DIMENSIONS
CONNECTION DETAILS
FIELD RECONFIGURATION
InputORDER CODE
MAIN FEATURES
OVERVIEW
The West 8600 temperature controller can measure and display the heater current. Special heater break alarms give early warning of element failure, to protect equipment and product. A soft-start feature is available for process warm up.