TECHNICAL DATA

Features
Control Types Full PID with Pre-tune, Self-tune, manual tuning, or On-Off control. Heat only or heat & cool
Auto/Manual Selectable from front panel or via digital input, with bumpless transfer
Output Configuration Up to 3 possible, for control, alarm, 24VDC transmitter power supply or retransmit of process value or setpoint
Alarm 1 & 2 Types Process high, process low, SP deviation, band, logical OR / AND. Also 1 loop alarm for process control security. Process alarms have adjustable hysteresis.
Human Interface 4 button operation, dual 4 digit 10mm & 8mm high LED displays, optional choice of colours (Red/Red, Red/Green, Green/Red or Green/Green), plus 5 LED indicators
PC Configuration Off-line configuration from PC serial port to dedicated config socket (comms option not required). Configuration Software for Windows 98 or higher. West Part Number: PS1-CON
   
Input
Thermocouple J, K, C, R, S, T, B, L, N & PtRh20%vsPtRh40%.
RTD 3 Wire PT100, 50 Ohm per lead maximum (balanced)
DC Linear 0 to 20mA, 4 to 20mA, 0 to 50mV, 10 to 50mV, 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V. Scaleable -1999 to 9999, with adjustable decimal point
Impedance >10M Ohm for Thermocouple and mV ranges, 47K Ohm for V ranges and 5 Ohm for mA ranges
Accuracy ±0.1% of input range ±1 LSD (T/C CJC better than 1°C)
Sampling 4 per second, 14 bit resolution approximately
Sensor Break Detection < 2 seconds (except zero based DC ranges), control O/P's turn off, high alarms activate for T/C and mV ranges, low alarms activate for RTD, mA or V ranges
   
Output and Options
Control & Alarm Relays Contacts SPDT 2 Amp resistive at 240V AC, >500,000 operations
Control SSR Driver Outputs Drive capability >10V DC in 500 Ohm minimum
Triac Outputs 0.01 to 1 Amp AC, 20 to 280Vrms, 47 to 63Hz
DC Linear Outputs 0 to 20mA, 4 to 20mA into 500 Ohm max, 0 to 10V, 2 to 10V, 0 to 5V into 500 Ohm min. Control outputs have 2% over/under drive applied. Accuracy ±0.25% at 250 Ohm (degrades linearly to 0.5% for increasing burden to specified limits)
Transmitter Power Supply Output 24VDC (nominal) into 910 Ohm minimum to power external devices
Serial Communications 2 Wire RS485, 1200 to 19200 Baud, Modbus and ASCII protocol (selectable)
Digital Input Selects between 2 setpoints or Auto/Manual control. Volt free or TTL input
Remote Setpoint Input 0 to 20mA, 4 to 20mA, 0 to 100mV, 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V or =2K Ohm Potentiometer Scaleable -1999 to 9999.
Local/Remote setpoint selected from digital input (supplied as part of Full RSP) or front panel
   
Operating and Environmental
Temperature & RH 0 to 55°C (-20 to 80°C storage), 20% to 95% RH non-condensing
Power Supply 100 to 240V 50/60Hz 7.5VA (optional 20 to 48V AC 7.5VA/22 to 65V DC 5 watts)
Front Panel Protection IEC IP66 (Behind panel protection is IP20)
Approvals and Certification CE, UL & ULC recognised

DIMENSIONS

CONNECTION DETAILS

FIELD RECONFIGURATION

Input
Jumper-free configuration for any type (no extra parts required) Option Slot 1
Relay Output (PO1-C10)
Linear mA/V DC Output (PO1-C21)
SSR Driver Output (PO1-C50)
Triac Output (PO1-C80)

Option Slot 2
Relay Output (PO2-C10)
Linear mA/V DC Output (PO2-C21)
SSR Driver Output (PO2-C50)
Triac Output (PO2-C80)

Option Slot 3
Relay Output (PO2-C10)
Linear mA/V DC Output (PO2-C21)
SSR Driver Output (PO2-C50)
24VDC Transmitter PSU (PO2-W08)

Option Slot
Digital Input (PA1-W03)
Remote Setpoint Input (Basic) (PA1-W04)
RS485 Comms (PA1-W06)

Option Slot B
Remote Setpoint Input (Full) (PB1-W0R)

ORDER CODE

MAIN FEATURES

  • Jumperless Configuration
  • Auto Detected Hardware
  • Process & Loop Alarms
  • Modbus & ASCII Comms
  • Auto or Manual Tuning
  • Heat/Cool Operation
  • Ramping Setpoint
  • Remote/Dual Setpoint Options

OVERVIEW

With its improved interface, technical functionality and field flexibility, the West 8100 gives you the best in comprehensive control for most temperature and process control loops.