West P6010 1/16 Din Panel Indicator

TECHNICAL DATA

Features
Output Configuration Up to 4 total. Max 3 single/1 dual relay, max 1 retransmit of PV, max 1 transmitter power supply
Alarms Up to 5. Process high low or logical OR (direct or reverse acting). With adjustable hysteresis
Viewable Values Process variable, maximum value, minimum value and alarm 1 elapsed time since reset
Human Interface 3 button operation, 4 digit 10mm high red or green display, plus 3 alarm 1 max and 1 min indicator
PC Configuration Off-line configuration from PC serial port to dedicated config socket (comms option not required). Configuration Software for Windows 98 or higher. West Part Number: PS1-CON
   
Input
Thermocouple J, K, C, R, S, T, B, L, N & PtRh20%vsPtRh40%.
RTD 3 Wire PT100, 50Ohm per lead maximum (balanced)
DC Linear 0 to 20mA, 4 to 20mA, 0 to 50mV, 10 to 50mV, 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V. Scaleable -1999 to 9999, with adjustable decimal point
Impedance >10MOhm for Thermocouple and mV ranges, 47KOhm for V ranges and 5Ohm for mA ranges
Accuracy ±0.1% of input range ±1 LSD (T/C CJC better than 1°C)
Sampling 4 per second, 14 bit resolution approximately
Sensor Break Detection < 2 seconds (except zero based DC ranges), high alarms activate for T/C, RTD and mV ranges, low alarms activate for mA or V ranges
   
Outputs and Options
Single Alarm Relays Contacts SPDT 2 Amp resistive at 240V AC, >500,000 operations. Latching or non-latching
Dual Alarm Relay Two x SPST contacts with shared common. 2 Amp resistive at 240V AC, >200,000 operations. Latching or non-latching
SSR Driver Outputs Drive capability >10V DC in 500Ohm minimum
Triac Outputs 0.01 to 1 Amp AC, 20 to 280Vrms, 47 to 63Hz
DC Linear Retransmit Outputs 0 to 20mA, 4 to 20mA into 500Ohm max, 0 to 10V, 2 to 10V, 0 to 5V into 500Ohm min. Accuracy ±0.25% at 250Ohm (degrades linearly to 0.5% for increasing burden to specified limits)
Transmitter Power Supply Output 24VDC (nominal) into 910Ohm minimum to power external devices
Serial Communications 2 Wire RS485, 1200 to 19200 Baud, Modbus and ASCII protocol (selectable)
Digital Input External reset of latched relay, stored alarm 1 elapsed time, stored min/max PV values or initiate tare function. Volt free or TTL input
   
Operating and Environmental
Temperature & RH 0 to 55°C (-20 to 80°C storage), 20% to 95% RH non-condensing
Power Supply 100 to 240V 50/60Hz 7.5VA (optional 20 to 48V AC 7.5VA/22 to 65V DC 5 watts)
Front Panel Protection IEC IP66 (Behind panel protection is IP20)
Standards CE, UL & ULC recognised. Pollution Degree 2, Installation Category II

DIMENSIONS

CONNECTION DETAILS

FIELD RECONFIGURATION

Input
Jumper-free configuration for any type(no extra parts required)

Option Slot 1
Relay Output (PO1-C10)
Linear mA/V DC Output (PO1-C21)
SSR Driver Output (PO1-C50)
Triac Output (PO1-C80)

Option Slot 2
Relay Output (PO2-C10)
Dual Relay Output (PO2-W09)
Linear mA/V DC Output (PO2-C21)
SSR Driver Output (PO2-C50)
Triac Output (PO2-C80)

Option Slot 3
Relay Output (PO2-C10)
Linear mA/V DC Output (PO2-C21)
SSR Driver Output (PO2-C50)
24VDC Transmitter PSU (PO2-W08)

Option Slot A
Digital Input (PA1-W03)
RS485 Comms (PA1-W06)

ORDER CODE

MAIN FEATURES

  • Jumperless Configuration
  • Auto Detected Hardware
  • Up to 4 Alarm Outputs
  • Modbus & ASCII Comms
  • Min/max Value Hold
  • Tare (auto-zero) Function
  • Multi-point Scaling
  • PC configuration

OVERVIEW

The P6010 has multi-point scaling, tare function and improved flexibility. It has a universal input and is available with a red or green display. Plug-in modules allow up to four alarm relays (latching or non-latching), PV retransmission or transmitter PSU.